Features:
- Measures 9 Parameters: Conductivity, Resistivity, TDS, Alkalinity,
- Hardness, LSI, pH, ORP, Free Chlorine Equivalent, Temperature
- LSI Calculator for hypothetical water balance calculations
- Autoranging delivers increased resolution across diverse applications
- Adjustable Temperature Compensation and Cond/TDS conversion ratios for user-defined solutions
- Nonvolatile memory of up to 100 readings for stored data protection
- Date & time stamp makes record-keeping a snap
- pH calibration prompts alert you when maintenance is required
- Auto-off minimizes energy consumption
- Low battery indicator
Applications:
- Circuit Board Cleanliness
- Deionized Water
- Fountain Solutions
- Horticulture
- Oxidation Reduction Potential (ORP)/Redox
- Reverse Osmosis
- Textile Manufacturing
The Ultrameter III 9P™ AHL Titration Kit, is based on the tried and tested design of the Ultrameter II™. The 9P adds the ability to perform in-cell alkalinity and hardness titrations either as stand-alone measurements or as part of an LSI calculation. Alkalinity, hardness, pH and temperature values can be manipulated in the LSI calculator to predict the effect of changes on water balance. Measurements are extremely accurate. And the 9P is simple to operate and maintain.
Accuracy You Can Trust
Like the Ultrameter I, the Ultrameter III 9 AHL Titration Kit delivers exceptional accuracy of ±1% of reading (±.1% at calibration point). This high level of accuracy is achieved through advanced four-electrode conductivity cell technology, a powerful microprocessor, proprietary circuit design and conversion algorithms for three of the most common solution types, as well as a unique pH/ORP sensor. With displayed values of up to 9999, the full four-digit LCD ensures resolution levels never before possible in such affordable instruments. For accuracy in diverse applications, Ultrameter III allows you to select from 3 solution modes that model the behavior of the most common solution types: KCl, NaCl and 442 Natural WaterTM. Additionally, the Ultrameter III features a user adjustable conductivity/TDS conversion ratio for greater accuracy when measuring solutions not contained in the microprocessor. The Ultrameter III is factory calibrated with NIST traceable solutions. Certification of traceability and NIST traceable standard solutions can be purchased as accessories for definitive calibration.
Innovative Engineering
The Ultrameter III is a prime example of how high-tech engineering can greatly simplify and streamline a task. Whether in the lab, industrial plant, or in a remote field location, electrometric measurements are accomplished in 3 easy steps:
- Fill the cell cup
- Push a parameter key
- Take the reading
Temperature compensation and range selection are both rapid and automatic. User adjustable temperature compensation (up to 9.99%/°C) which can also be disabled for applications requiring non-compensated readings. Digital results display instantly. Measurement is continuous, displaying real-time readings rather than a static snapshot of the solution.
Easy to Calibrate
All calibrations are quickly accomplished by pressing the keys to agree with NIST traceable Standard Solution. When calibration is necessary, display prompts simplify pH calibration and make sure the correct buffer is being used. Plus, all parameters (excluding factory set temperature) have an internal electronic setting that can be used for field calibration and as a check on pH/ORP sensor life.
FCE TM FAC Readings
The Myron L® Company FCE function reports FAC quickly and accurately by measuring ORP, the chemical characteristic of chlorine that directly reflects its effectivity, cross referenced with pH. Both DPD kits and colorimeters may tell the user the FAC value of the sample in the test tube, but since the chemistry of that sample is quite different from the source water being analyzed, the results are imprecisely related to actual disinfection power. The Myron L® Company FCE function measures the real, unaltered chemistry of source water, including Ωent-to-Ωent changes in that chemistry.
Alkalinity & Hardness Titration Kit & LSI Calculator
A hard foam-lined case organizes and protects all contents: The 9P; 9P cell extender; required reagents for in-cell alkalinity and hardness titrations; standard calibration solutions for all parameters; storage solution to protect the pH/ ORP sensor; and pipette for precision dispensing with additional tips. Sensors are internal and included.
9P Titration Kit
Includes 9P; cell extender; titration plunger; 100µL pipette; 12 tips; 3 buffers (pH 4, 7, and 10); pH/ORP Sensor Storage Solution; ORP Conditioner Solution; titration reagents and standards H2SO4-1, HBUFF, EDTA-B-LC, EDTA-B-HC, Alkalinity Standard 100 and Hardness Standard 200; standard solutions KCl-7000 and 442-3000. All bottles are 2 oz/59 mL. model: 9PTKB
In-Cell Titration Functions
The Ultrameter IIITM adds the ability to perform in-cell conductometric titrations that provides a convenient way to determine alkalinity, hardness and LSI in the field. This eliminates the need to collect and transport samples to another location for analysis. User intuitive display prompts guide you through titration procedures from start to finish. All required reagents and equipment are included in the 9P titration kit.
Hardness Unit Conversion
The Hardness titration feature allows you to set the hardness unit preference to either grains of hardness or Ppm CaCO3. The selected hardness unit is also used in the LSI calculator functions.
For more information, please see Data Sheet and Manual